Calvert Formula, Traub

GFR, Traub

Calvert formula: Calculates carboplatin dose by targeting a desired AUC using measured or estimated GFR (Calvert et al. 1989 1).
Traub formula: Estimates carboplatin clearance using patient-specific pharmacokinetic parameters to individualize dosing (Newell et al. 1993 2).

mg/dlmcmol/L
mg/ml*min

Indicações de Uso

Used to individualize carboplatin dosing by targeting AUC based on measured/accurate GFR, especially when renal function strongly determines exposure. Clinically useful for avoiding under‑/overdosing, improving precision when creatinine-based estimates are unreliable (e.g., oncology patients where eGFRcr alone overdoses 10–20% 1).

Traub applied for pediatric carboplatin dosing when renal function is key; improves AUC precision vs BSA dosing and reduces variability in exposure 2.

Insights e Precauções

Start with accurate GFR, as wrong inputs drive major dose errors. The Calvert approach can overdose when Cockcroft–Gault or non‑adjusted creatinine is used; enzymatic creatinine requires +0.2 mg/dL adjustment to avoid toxicity 1 [Level II evidence]. eGFRcr‑cys improves accuracy and reduces carboplatin overdosing by 3–4× versus creatinine alone 2 [Level II evidence]. Measured GFR is preferred when the therapeutic index is narrow or renal function atypical 3 [Level I evidence].