Calvert Formula, Shull

GFR, Shull

Calvert formula: Calculates carboplatin dose by targeting an AUC using the patient’s GFR plus a fixed nonrenal clearance component 1 [Level I evidence].
Shull formula: Provides pharmacokinetically guided carboplatin dosing based on individualized clearance estimates in pediatric patients 2 [Level I evidence].

mg/dlmcmol/L
yrs
mg/ml*min

사용 적응증

Used to individualize carboplatin dosing based on renal function by targeting an AUC: dose = AUC × (GFR + 25). Indicated when carboplatin exposure must be precise (e.g., ovarian, lung, germ‑cell cancers) and renal function varies; clinically useful because carboplatin clearance correlates linearly with GFR, ensuring predictable toxicity and avoiding under/overdosing 1 [Level I evidence].

통찰 및 주의사항

Start by emphasizing that dose accuracy depends entirely on true GFR, which is often misestimated in cancer patients.

  • Use measured GFR or eGFRcr‑cys when possible to avoid 10–20% overdosing seen with creatinine‑only estimates 1.
  • Be cautious in renal insufficiency: the +25 mL/min non‑renal clearance term can overestimate clearance, leading to overdosing in Japanese cohorts 2.
  • Avoid unadjusted Cockcroft‑Gault, which frequently misdoses (over- or under-) compared with isotopic GFR 3.

Shull/Chatelut-derived approaches assume stable creatinine and body composition; performance degrades in low-dose settings, extremes of weight, or sarcopenia, with up to 40% overestimation of clearance 4.