Production of CO2

normal ranges: 160-220 ml/min

Carbon dioxide production is the generation of CO2 as a byproduct of cellular energy metabolism.

kglbs
ml/kg/min

Indications d'utilisation

Used to estimate resting energy expenditure when indirect calorimetry is unavailable, using ventilator‑derived VCO₂ to guide nutrition in mechanically ventilated ICU patients (more accurate than predictive equations) 1 [Level I evidence]. Also useful as a marker of perfusion adequacy in shock when paired with ∆PCO₂ or ∆PCO₂/ΔCvO₂ ratios 2 [Level II evidence]. Helps detect metabolic deterioration (falling VCO₂) in sepsis 3 [Level II evidence].

Informations et précautions

CO2 production reflects metabolic rate and rises with fever, sepsis, catecholamines, overfeeding, or dobutamine-driven increases in VO2/VCO2 1 [Level II evidence].
Cautions:

  • Ventilator‑derived VCO2 estimates are less accurate than indirect calorimetry and may misestimate energy expenditure 2 [Level II evidence].
  • CKRT removes ~14% of expired CO2, distorting VCO2‑based calculations 3 [Level II evidence].
  • Sudden unexplained CO2 surges should raise suspicion for malignant hyperthermia 4 [Level III evidence].