Calvert Formula, Hull

GFR, Hull

Calvert Formula: Calculates carboplatin dose using target AUC and GFR to individualize exposure.
Hull Formula: Estimates creatinine clearance using adjusted body weight to improve accuracy in obese patients.

mg/dlmcmol/L
kglbs
Gender
Female+0.85Male+1
mg/ml*min
yrs

Indications for Use

Used to dose carboplatin by targeting AUC when renal function determines clearance. Indicated for adults receiving carboplatin where individualized exposure is required; preferred when GFR is measured or accurately estimated. Clinically useful because carboplatin clearance is linearly related to GFR, enabling predictable AUC‑based dosing and toxicity control (original validation n=31; r=0.886) 1 [Level I evidence]. Combination regimens and prior therapy require selecting appropriate target AUC.

Insights & Cautions

Start with measured or cystatin‑C–creatinine eGFR when possible to reduce overdose risk; eGFRcr alone can overdose 10–20% of patients 1.

  • Enzymatic creatinine requires +0.2 mg/dL adjustment to avoid severe thrombocytopenia 2.
  • Cockcroft‑Gault frequently misestimates GFR and should be used cautiously, especially at weight extremes 3.
  • Hull/adjusted formulas improve bias but remain unreliable in sarcopenia or unstable renal function.