Calvert Formula, Gates (f)
GFR, Gates
Calvert Formula: Calculates the carboplatin dose by target AUC × (GFR + 25) to individualize exposure.
Gates (f): Estimates renal function from radionuclide renal scan uptake.
mg/dlmcmol/L
yrs
mg/ml*min
Indications for Use
Used to determine carboplatin dose from renal function and to estimate renal clearance when accurate GFR is required.
- Indications: Renal‑function–based carboplatin dosing where drug exposure must match a target AUC; preferred when GFR is measured or reliably estimated because carboplatin clearance correlates linearly with GFR 1 [Level I evidence].
- Clinical utility: Minimizes over/underdosing; avoids toxicity from GFR overestimation, especially when creatinine-based estimates are inaccurate in cancer populations 2 [Level II evidence].
Insights & Cautions
Use measured GFR when accuracy matters; eGFRcr alone commonly misestimates kidney function in cancer and risks carboplatin misdosing 1 [Level II evidence].
- Calvert: Errors mainly arise from inaccurate GFR; cystatin‑C–creatinine equations improve dosing accuracy; avoid Cockcroft‑Gault in oncology due to frequent over/underdosing 1 [Level II evidence].
- Gates (f): 99mTc‑DTPA scintigraphy is substantially less accurate than measured GFR and not recommended for drug dosing per KDIGO 2024 2 [Level I evidence].